2024年1月6日发(作者:)
1.如何安装多层多道(老版)
1). Make a new Directory:(建立一个新文件夹)
C:KRCTPMultiLayerTemplate
2). Copy the following files into the new directory:(将下列文件复制到新文件夹中)
-
- vorgabe_
- vorgabe_
3). Make a new directory: (建立一个新文件夹)
R1TPMultiLayer
4). Copy the following files into the new directory: (将下列文件复制到新文件夹中)
-
-
- multilayer_
- multilayer_
- multilayer_
- multilayer_
5). Add the part of the files into the adequate files:(将下面的部分对应添加)
- add_to_$(在config最下面写)
;fold multilayer globals
Decl real rml_circ_h_val
Decl bool bml_circ_active = false
Decl int iml_sens_typ
Decl bool bml_circ_h = false
;endfold
- add_to_
在C:/ KRC / ROBOTER / INIT / menukeyuser . ini分三部分对应添加
- add_to_(在SPS下的;please insert user defined initialization commands下面写)
;fold multilayer init
bml_circ_active = false
rml_circ_h_val = -9999.9
;fold
LOOP(该LOOP为程序自带)
;fold multilayer
ml_ct_sps ( )
;endfold
6). replace the driver for the LiBo-Card
把多层多道文件下的libodrv.o复制到- C:KRCROBOTERDrivers 中,把原来的C:KRCROBOTERDriverslibodrv.o覆盖掉
7). Run the file to add the registry entries (if needs to be removed use the
)(意思是在WINDOWS状态下自己的多层多道文件夹下把程序运行一遍)
2.如何卸载和装新的KRC:
1
在WINDOWS状态下把C:/ KRC / ROBOTER / INIT和KRC删除掉,冷启动后,把右下角的原KRC右击关闭,用光盘装新KRC
关于如何把填弧坑时间改长:
点’开始”---运行regedit---hkey_current_user/ software/ vb and vba program settings/ kukatparc/
end_ti,双击右面的MAX,输入5,点确认!
3.如何做备份:
在WINDOWS状态下打开C:/ KRC / UTIL / urator/,先把路径移除,再将PATH改为D盘,增加路径后应用。如要备份,用archive进行备份,如果想要备份新的东西,而原来的备份又有用,请将D盘中archive文件名改为其他名字,可以在后面加数字或别的字母,因为archive是默认文件,如果不改,则第二次做的备份将直接把第一次的备份覆盖掉!
4.如何卸载弧焊,寻位软件包:
在WINDOWS状态下打开C:/ KRC_OPTION后,找到对应的弧焊,寻位等,点击uninstall即可,冷启动后就OK!
5.如何设置KUKA外部轴点动
(以外部轴E1为例)
1.$ASYNC_OPT=TRUE (KRC/STEU/MADA/)
;2-4条命令都在KRC/STEU/MADA/
2.$ASYNC_AX1_P $IN[9] (输入信号9控制E1轴点动的正方向)
3.$ASYNC_AX1_N $IN[10] (输入信号10控制E1轴点动的负方向)
4.$ZUST_ASYNC $IN[X] (使能:设置和move_enable一样的信号即可)
5.$ASYNC_AXIS='B00001' (1表示为此时E1是不同步轴,可以点动。此命令必须在机器人程序里写,并运行后才有效,退出程序后 $ASYNC_AXIS的值自动会变回'B00000',所有轴都是同步轴了,不能点动了。)
6.如何在SPS中写防碰撞及在外部自动中设防碰撞信号
Sps下面写防碰撞,防碰撞触发后,在T1模式下移动焊枪,短接in和out信号(短接为任意的,只要是空端子就行,在下面的程序中以N代替,具体看实际情况)
If ($in[防碰撞信号] and $in[按钮盒停止信号]) or ($T1 and not $in[防碰撞信号] and
$in[按钮盒停止信号]) == true then
$out[N]=true
Else
$out[N]=false
endif
在T1模式下将机器人手动速度改慢:
If $T1==true then
2
$ov_jog=10
endif
外部自动配置
1:3 ;2:0 ;3(有几个工位写几);4(工位一启动信号):具体看图纸;5:0 ;6:0;
7(外部启动信号)具体看图纸;8(防碰撞短接输入信号):具体看短接点;9(报警复位信号):具体看图纸 ;10:默认;11:默认 12(防碰撞短接输入信号):具体看短接点
4(三色灯黄灯,如果没有三色灯,可以不设):具体看图纸
7(三色灯红灯及按钮盒报警指示灯信号):具体看图纸
3
1三色灯绿灯及按钮盒程序运行指示灯:具体看图纸(program active)
3.工位运行指示灯(application running),在单工位情况下,直接输入对应信号,如果是双工位,就保持默认值,在SPS 下面写
1. Home 位置对应指示灯:具体看图纸
其余均为默认!
7.如何防止气缸误操作:
防止气缸误操作SPS下面写(利用监测单轴的范围,其中输入N是气缸锁紧的检测开关信号,如在气缸锁紧的情况下误操作了被锁紧的外部轴,此时会报警,不允许动作,此时打开气缸即可解除报警)
If $in[N] == true then
$AXWORKSPACE[1].MODE = #OUTSIDE_STOP
Else
$AXWORKSPACE[1].MODE = #OFF
Endif
设置检测轴范围的操作如下:(根据实际情况设置范围,如-0.1°~+0.1°)
4
8. 如何在没有外部启动的情况下进行双工位调用和设工位运行指示灯(sps下面写)
if st < 150 then
$flag[50] = true
st = st + 1
else
if st < 300 then
$flag[50] = false
st = st + 1
else
st = 0
endif
endif
;****************************
;*****************************
;station_1 release ?
;*****************************
IF $IN[工位一启动信号]==false then
$flag[16]=false
endif
if ($in[工位一启动信号] and not $flag[16] and not $flag[17])==true then
$flag[16]=true
$flag[17]=true
endif
if ($in[工位一启动信号] and not $flag[16])==true then
$flag[16]=true
5
$flag[17]=false
endif
if $flag[17]==true then
$flag[11]=true
else
$flag[11]=false
endif
if ($flag[13] or not $flag[17])==true then
$flag[11]=false
$flag[17]=false
endif
if ($flag[50] and $out[绿灯]) or ($flag[11] and $out[绿灯]) ==true then
$out[工位一运行指示灯]=true
else
$out[工位一运行指示灯]=false
endif
;*********************************************
;station_2 release ?
;*********************************************
if $in[工位二启动信号]==false then
$flag[26]=false
endif
if ($in[工位二启动信号] and not $flag[26] and not $flag[27])==true then
$flag[26]=true
$flag[27]=true
endif
if ($in[工位二启动信号] and not $flag[26])==true then
$flag[26]=true
$flag[27]=false
endif
if $flag[27]==true then
$flag[21]=true
else
$flag[21]=false
endif
if ($flag[23] or not $flag[27])==true then
$flag[21]=false
$flag[27]=false
endif
if ($flag[50] and $out[绿灯]) or ($flag[21] and $out[绿灯])==true then
$out[工位二运行指示灯]=true
6
else
$out[工位二运行指示灯]=false
Endif
9.有外部启动的双工位情况,直接在CELL中调用程序,双工位运行指示灯在SPS中如下写:
If $in[工位一输入信号] == true then
$flag[11]=true
Endif
If $in[工位二输入信号]==true then
$flag[12]=true
Endif
If $flag[11] and $out[程序运行指示灯] and not $out[工位二运行指示灯]==true then
$out[工位一运行指示灯]=true
Else
$out[工位一运行指示灯]=false
Endif
If $flag[12] and $out[程序运行指示灯] and not $out[工位一运行指示灯]==true then
$out[工位二运行指示灯]=true
Else
$out[工位二运行指示灯]=false
Endif
10.福尼斯双丝如何在机器人里面设双丝焊电压电流参数(可在编程序时直接设置的)
1.首先增加通道,将config/autoext globals中的int a_act_an_max=2改为4,并初始化一下
2.在windows 状态下运行regedit进入Hkey_current_user/software/VB and
VBA program settings,把ANA3_E的参数改为与ANA1_E一样,把ANA4_E的参数改为与ANA2_E一样;把S_ANA3的参数改为与把S_ANA1一样,把S_ANA4的参数改为与把S_ANA2一样;把W_ANA3的参数改为与把W_ANA1一样,把W_ANA4的参数改为与把W_ANA2一样;把UNIT13的参数改为与把UNIT11一样,把UNIT14的参数改为与把UNIT12一样;并初始化一下
3.在windows 状态下打开KRC/UTIL/DBTEXTCONVERT文件夹下面的arctech_将其中的
backgroud level(start11,weld11,carterchannel11后面的)改为voltage1;
Wire feed (start12,weld12,carterchannel12后面的)改为wire feed1;
7
inductance(start13,weld13,carterchannel13后面的)改为voltage2;
pulse level(start14,weld14,carterchannel14后面的)改为wire feed1;
4.进入setup/service/longtext中点第一项longtext—database,找到KRC/UTIL/DBTEXTCONVERT文件夹下面的arctech_文件,点击下面的“对”号进行文件导入,导入完毕后,初始化一下,
5.进入程序后即可看到有两个电压电流参数可设!
11.福尼斯双丝:
1).I/O配置,首先在KRC/ROBOTER/INIT/DEVENT中增加地址 [2] macid=10,地址1和波特率都不用改!
Inb0=5,0,x
Outb0=5,0,x
inb50=10,0,x4
inb58=10,8,x4
inb66=10,16,x4
outb50=10,0,x4
outb58=10,8,x4
outb66=10,16,x4
anin2=10,4,16,2
anin1=10,6,16,2
anin4=10,12,16,2
anin3=10,14,16,2
anout2=10,4,16,2
anout1=10,6,16,2
anout4=10,12,16,2
anout3=10,14,16,2
2)福尼斯双丝CONFIG中需设置如下信号
1.输出weld-start 401; weld mode 403;gas preflow 409; WFD+ 410; WFD- 411; receipt error 412
2.输入weld ready 406; arc establish 401
3.寻位413
4.MODE CHAN 11下第一行把PARA的值改为13;第二行把PARA的值改为39,val改为1.0;第三行把PARA的值改为40,第四行把PARA的值改为41,第五行把PARA的值改为42
MODE CHAN 12下把1000都改为500
MODE CHAN 13改为与MODE CHAN 11一样
MODE CHAN 14改为与MODE CHAN 12一样
5.在USER GLOBALS下面写(用于调用程序号和配合SPS使用的)
Signal progno $out【425】 to $out[431]
8
Decl bool bfronius_stop=true
3)福尼斯双丝焊SPS下面需写的东西
;Torch sensing
if $in[401] == true then
$out[N] = true (N为快速测量输出信号)
else
$out[N] = false
Endif
;Robot ready bit
IF ($PERI_RDY==TRUE) THEN
$OUT[402]=true
endif
IF (($peri_RDY==FALSE) and ($stopmess==true)) then
;$out[402]=not($peri_RDY==false)
bFRONIUS_stop=$stopmess
endif
if (($PERI_rdy == true) and (bFRONIUS_stop==true) and ($in[406]==false)) then
bFRONIUS_stop=false
pulse ($out[412],true,1.0)
endif
;move enable
if ($in[405] and $in[407] and $in[工位1停止按钮] and $in[工位2停止按钮]) or
($T1 and not $in[405] and $in[407] and $in[工位1停止按钮] and $in[工位2停止按钮] ) == true then
$out[15] = true
else
$out[15] = false
4)为了方便了解福尼斯双丝ini_start中写的输入输出点含义,进行I/0注解
1. 输入arc establish 401;power ready 406;touch collision 405
2. 输出weld-start 401; robot ready 402;bit 0 modes 403; bit 1 modes 404; bit 2 modes 405;
Master power1 406; Master power2 407;gas test 409; WFD+ 410; WFD- 411; source error
reset 412;touch sensing 413
5)福尼斯双丝建立ini_start程序,定义焊接的一些功能,在编程序使用前先调用该程序
;*****************************
;robot ready
OUT 402 'Robot ready' State= TRUE
9
OUT 1 '' State= TRUE
;****************************
;power source error reset
PULSE 412 'Source error reset' State= TRUE Time= 0.5 sec
;**********************
;operating mode
OUT 403 'Bits 0 modes' State= TRUE
OUT 404 'Bits 1 modes' State= FALSE
OUT 405 'Bits 2 modes' State= FALSE
;****************************
;twin power master select
OUT 406 'Master power 1' State= TRUE
OUT 407 'Master power 2' State= FALSE
;**************************
;program NR
progno = 8
;**********************
;dynamic power source 1
OUT 469 '' State= TRUE
OUT 465 '' State= TRUE
OUT 466 '' State= TRUE
OUT 467 '' State= TRUE
OUT 468 '' State= TRUE
OUT 470 '' State= TRUE
OUT 471 '' State= TRUE
OUT 472 '' State= FALSE
;************************
;dynamic power source 2
OUT 529 '' State= TRUE
OUT 530 '' State= TRUE
OUT 531 '' State= TRUE
OUT 532 '' State= TRUE
OUT 533 '' State= TRUE
OUT 534 '' State= TRUE
OUT 535 '' State= TRUE
OUT 536 '' State= FALSE
;*************************
10
;burn back power source 1
OUT 477 '' State= FALSE
OUT 478 '' State= FALSE
OUT 479 '' State= FALSE
OUT 480 '' State= TRUE
;**************************
;burn back power source 2
OUT 541 '' State= FALSE
OUT 542 '' State= FALSE
OUT 543 '' State= FALSE
OUT 544 '' State= TRUE
12.福尼斯单丝:
1).福尼斯单丝I/O配置,首先在KRC/ROBOTER/INIT/DEVENT中增加地址 [2]
macid=11,地址1和波特率都不用改!
inb0=5,0,x
outb0=5,0,x
inb5=11,0,x4
inb9=11,8,x4
outb5=11,0,x4
outb9=11,8,x2
anin2=11,4,16,2
anin1=11,6,16,2
;anin3=11,8,16,2
;anin4=11,10,16,2
anout2=11,4,16,2
anout1=11,6,16,2
;anout3=11,8,16,2
;anout4=11,10,16,2
2).福尼斯单丝CONFIG中设置输入输出信号
输出weld-start 41; gas preflow 49; WFD+ 50; WFD- 51
输入weld ready 46; arc establish 41
寻位53
3).福尼斯单丝焊SPS下面需写的东西
;Torch sensing
if $in[41] == true then
$out[快速测量接口信号] = true
11
else
$out[快速测量接口信号] = false
endif
if ($t1 and not $in[45] and $in[47]) or ($in[45] and $in[47]) ==true then
$out[16]=true
else
$out[16]=false
Endif
4).福尼斯单丝建立ini_start程序,定义焊接的一些功能,在编程序使用前先调用该程序
;robot ready
OUT 42 'robot ready' State=TRUE
;power source error reset
PULSE 52 'error reset' State=TRUE Time=0.5 sec
;operating mode
OUT 43 'bit 0' State=FALSE
OUT 44 'bit 1' State=FALSE
OUT 45 'bit 2' State=FALSE
;twin power master select
OUT 46 '' State= TRUE CONT
;program NR
OUT 65 '' State= TRUE
OUT 66 '' State= FALSE
OUT 67 '' State= FALSE
OUT 68 '' State= TRUE
OUT 69 '' State= FALSE
OUT 70 '' State= FALSE
OUT 71 '' State= TRUE
;dynamic power source 1
OUT 73 '' State= TRUE
OUT 74 '' State= TRUE
OUT 75 '' State= FALSE
OUT 76 '' State= FALSE
OUT 77 '' State= FALSE
OUT 78 '' State= FALSE
OUT 79 '' State= FALSE
12
OUT 80 '' State= TRUE
;dynamic power source 2
;burn back power source 1
OUT 81 '' State= FALSE
OUT 82 '' State= FALSE
OUT 83 '' State= FALSE
OUT 84 '' State= TRUE
OUT 85 '' State= TRUE
OUT 86 '' State= FALSE
OUT 87 '' State= FALSE
OUT 88 '' State= FALSE
;burn back power source 2
OUT 43 'bit 0' State= TRUE
END
5).如何测福尼斯电阻
1. 进入二级菜单
2. 选择R
3. 拆除喷嘴将导电嘴接触工件
4. 点动送丝信号或启弧信号
5. 观察屏幕,显示RUN
6. 计算结果通常7-15,有时也会20
****福尼斯单丝
1).I/O配置,首先在KRC/ROBOTER/INIT/DEVENT中增加地址 [2] macid=11,地址1和波特率都不用改!
inb0=5,0,x
outb0=5,0,x
inb50=11,0,x12
outb50=11,0,x4
outb58=11,8,x4
anout2=11,4,16,2
anout1=11,6,16,2
2).福尼斯TIG单丝建立ini_start程序,定义焊接的一些功能,在编程序使用
13
前先调用该程序
;robot ready and Tig mode
OUT 402 'rob_ready' State= TRUE
OUT 404 'TIG' State= TRUE
OUT 405 'TIG' State= TRUE
PULSE 412 'error_reset' State= TRUE Time= 0.5 sec
;basic current
OUT 465 '' State= FALSE
OUT 466 '' State= FALSE
OUT 467 '' State= FALSE
OUT 468 '' State= FALSE
OUT 469 '' State= FALSE
OUT 470 '' State= TRUE
OUT 471 '' State= FALSE
OUT 472 '' State= TRUE
;dcy
OUT 473 '' State= FALSE
OUT 474 '' State= FALSE
OUT 475 '' State= FALSE
OUT 476 '' State= FALSE
OUT 477 '' State= FALSE
OUT 478 '' State= FALSE
OUT 479 '' State= FALSE
OUT 480 '' State= TRUE
END
14).如何设光栅(只在自动和外部自动才能检测)
1.KRC/STEU/MADA/$里的
signal $safegate_op $in[x];safety gate on path sto;x为输入信号
2. 把外部自动的HOME POSITION 改为输出信号【Y】, Y为输出信号
15).如何做镜像文件和导入文件
1. 开机后按F10,选ENGLISH
2. 点2创建一个新的镜像
3. 做好后会跳出一行英文check the imagefile,等待自动跳完,关机后拔出U盘4. 导入文件,方法同上,不同是第2步按1,还原1个镜像文件
16).如何设艾默生变频器的外部故障点(主要用于急停时候用)
假设接了x5和com点,在F7—F7.04—把0改为6
14
17).KUKA机器人X11中的短接
1,2短接,3,4短接,5,6短接7,8短接,19,20短接,21,22短接,23,24短接,25,26短接,41,42短接,38,50短接,39,51短接
如果有外部急停按钮,直接将1,4接急停按钮的一组常闭点,将19,22接急停按钮的另一组常闭点
18).KUKA机器人外部轴伺服放大器中的短接
1,2短接,4,5短接,4,6短接
19).KUKA机器人外部轴伺服放大器对应电机
KSD8—1.5KW, KSD16—2.5KW, KSD32—3.2KW/4,2KW, KSD64—8.3KW
如果电机与伺服放大器不匹配,会导致电机无法启动或者能启动,但是震动很大,速度很慢!!
20).DEVICENET CAN接线
一端+V(红),can H(白),shield(屏蔽线),can L(蓝),-V(黑)
另一端5(红),4(白),3(屏蔽线),2(蓝),1(黑)
接在WAGO或BECKOFF 模块的那一端需在白,蓝线之际加一个120欧姆的电阻
21). EWM单丝
1).I/O配置,首先在KRC/ROBOTER/INIT/DEVENT中增加地址 [2] macid=1,地址1和波特率都不用改!将总线接口的拨码开关1和8拨上,1代表波特率为500K,8代表地址为1
inb0=5,0,x
outb0=5,0,x
inb5=1,0,x4
outb5=1,0,x4
anin1=1,4,16,3
anin2=1,6,16,3
anin3=1,8,16,3
anin4=1,10,16,3
anout2=1,4,16,3(电压)
anout1=1,6,16,3(电流)
anout3=1,8,16,3(动特性)
2).EWM单丝CONFIG中设置输入输出信号
输出weld-start 45; gas preflow 47; weld mode ps/mm 43;WFD+ 49; WFD- 51
输入weld ready 42; arc establish 41
寻位50
15
21). EWM双丝
1).EWM双丝I/O配置,首先在KRC/ROBOTER/INIT/DEVENT中增加地址 [2]
macid=1,地址1和波特率都不用改!将总线接口的拨码开关1和8拨上,1代表波特率为500K,8代表地址为1;增加地址 [3] macid=2,地址1和波特率都不用改!将总线接口的拨码开关1和7拨上,1代表波特率为500K,7代表地址为2
inb0=5,0,x
outb0=5,0,x
inb5=1,0,x4
outb5=1,0,x4
anout2=1,4,16,3(电压)
anout1=1,6,16,3(电流)
anout5=1,8,16,3(动特性)
inb50=2,0,x4
outb50=2,0,x4
anout4=2,4,16,3(电压)
anout3=2,6,16,3(电流)
anout6=2,8,16,3(动特性)
2).EWM双丝CONFIG中设置输入输出信号
输出weld-start 45; gas preflow 47; weld mode ps/mm 43;WFD+ 49; WFD- 51
输入weld ready 42; arc establish 41 寻位50
在USER GLOBALS下面写(用于调用程序号和配合ini-star程序使用的)
Signal progno $out【425】 to $out[431]
Decl bool bfronius_stop=true
3).为使辅丝起作用,需在EWM双丝 SPS中写
if $out[45] == true then
$out[405] = true
else
$out[405] = false
endif
if $out[47] == true then
$out[407] = true
else
$out[407] = false
endif
if $out[49] == true then
$out[409] = true
else
16
$out[409] = false
endif
if $out[51] == true then
$out[411] = true
else
$out[411] = false
endif
if $in[41] or $in[401] == true then
$out[寻位信号] = true
else
$out[寻位信号] = false
endif
if ($in[防碰撞] and $in[停止信号] ) or ($t1 and not $in[防碰撞] and $in[停止信号] )
== true then
$out[16]=true
else
$out[16]=false
endif
if $t1==true then
$ov_jog=10
Endif
4). EWM双丝 建立ini_start 程序
DEF ini_start( )
;Robo ready
OUT 46 '' State= TRUE
OUT 406 '' State= TRUE
;Error reset
PULSE 53 '' State= TRUE Time= 0.5 sec
PULSE 413 '' State= TRUE Time= 0.5 sec
;Dynamics
ANOUT CHANNEL_5 = 0.5
ANOUT CHANNEL_6 = 0.52
; master or slaver
OUT 64 '' State= TRUE
OUT 424 '' State= FALSE
;progno
progno1 = 9
progno2 = 9
;Plus
OUT 43 '' State= TRUE
OUT 403 '' State= TRUE
END
17
发布者:admin,转转请注明出处:http://www.yc00.com/news/1704477288a1353727.html